Benchtop centrifuges

Specialists in diversity

Hettich manufactures a complete range of benchtop centrifuges for nearly every standard laboratory application. Multiple units, rotors and accessories ensure throughput demands are met, no matter what the volume. Robust and steady temperature control systems ensure your samples are kept at the optimal sample temperature, with both cooled and heated models available. In addition to standard laboratory applications, many specialty applications can be accommodated via our vast library of accessories and our custom built options for those have unique challenges.

ROTOFIX 46 | 46 H

Robust industrial unit

ROTANTA 460 | 460 R

Superior benchtop for multi-purpose use

ROTINA 420 | 420 R

Well equipped for all lab applications

ROTINA 380 | 380 R

High speed with space saving design

UNIVERSAL 320 | 320 R

Your universal choice

ROTOFIX 32 A

Rugged and indispensable

Long-term solutions for your evolving laboratory

Hettich manufactures an extensive range of general purpose benchtop centrifuges for nearly any standard laboratory application. We offer long-term solutions for your evolving laboratory.

   

Speciality applications, capability beyond the bench

Specialty accessories expand our capability beyond the standard clinical laboratory setting into agriculture, food and beverage, petrochemical and more. Various temperature control options are available.

Diverse range of accessories for multiple applications

Versatile rotors accommodate multiple applications - saving you from purchasing additional hardware. A vast range of accessories ensure capacity and specification needs are met. 

Optional bio-containment and phenol-resistant lids for safe centrifugation of hazardous samples are available. Moveable cabinets extend your bench space to provide extra storage and centrifuge portability.

Packages
ROTOFIX 32 A Blood Tube Package 1
  • 1x | 1206 | ROTOFIX 32 A Centrifuge
  • 1x | 1624 | Swing-out rotor, 4-place
  • 4x | 1481 | Buckets 
  • 4x | 1492 | Lids (bioseal)
  • 4x | 1383 | Adapters 5-place 
  • 4x | 1348 | Adapters 4-place
ROTANTA 460 Conical Package 1
  • 1x | 5650 | ROTANTA 460 Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5683 | Adapters 24-place
  • 4x | 5686 | Adapters 10-place
ROTANTA 460 Conical Package 2
  • 1x | 5650 | ROTANTA 460 Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4885 | Buckets
  • 4x | 4839 | Adapters 14-place
  • 4x | 5647 | Adapters 7-place
ROTANTA 460 R Conical Package 1
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4890 | Buckets
  • 4x | 4883 | Lids (bioseal)
  • 4x | 4469 | Adapters 14-place
  • 4x | 4468 | Adapters 7-place
ROTANTA 460 R Conical Package 2
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5683 | Adapters 24-place
  • 4x | 5686 | Adapters 10-place
ROTANTA 460 R Conical Package 3
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4885 | Buckets
  • 4x | 4839 | Adapters 14-place
  • 4x | 5647 | Adapters 7-place
ROTANTA 460 R Blood Tube Package 4
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5652 | Lid (bioseal)
  • 4x | 5685 | Adapters 47-place
  • 4x | 5682 | Adapters 37-place
ROTANTA 460 R Blood Tube Package 5
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4880 | Buckets
  • 4x | 4883 | Lid (bioseal)
  • 4x | 4847 | Adapters 27-place
  • 4x | 4848 | Adapters 22-place
ROTINA 380 Blood Tube Package 1
  • 1x | 1701 | ROTINA 380 Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1751 | Lids (bioseal)
  • 4x | 1783-A | Adapters 16-place
  • 4x | 1763-A | Adapters 13-place
ROTINA 380 Conical Package 2
  • 1x | 1701 | ROTINA 380 Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1771-A | Adapters 9-place
  • 4x | 1772-A | Adapters 4-place
ROTINA 380 R Conical Package 1
  • 1x | 1706 | ROTINA 380 R Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1771-A | Adapters 9-place
  • 4x | 1772-A | Adapters 4-place
ROTINA 380 R Blood Tube Package 2
  • 1x | 1706 | ROTINA 380 R Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1751 | Lids (bioseal)
  • 4x | 1783-A | Adapters 16-place
  • 4x | 1763-A | Adapters 13-place
ROTINA 420 Blood Tube Package 1
  • 1x | 4701 | ROTINA 420 Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4780 | Buckets
  • 4x | 4783 | Lids (bioseal)
  • 4x | 4762A | Adapters 26-place
  • 4x | 4763 | Adapters 18-place
ROTINA 420 Conical Package 2
  • 1x | 4701 | ROTINA 420 Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4785 | Buckets
  • 4x | 4769 | Adapters 13-place
  • 4x | 4770 | Adapters 5-place
ROTINA 420 R Blood Tube Package 1
  • 1x | 4706 | ROTINA 420 R Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4780 | Buckets
  • 4x | 4783 | Lids (bioseal)
  • 4x | 4762 | Adapters 26-place
  • 4x | 4763 | Adapters 18-place

 

ROTINA 420 R Conical Package 2
  • 1x | 4706 | ROTINA 420 R Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4785 | Buckets
  • 4x | 4769 | Adapters 13-place
  • 4x | 4770 | Adapters 5-place
UNIVERSAL 320 Blood Tube Package 1
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1425 | Buckets
  • 4x | 1438 | Adapters 7-place
  • 4x | 1441 | Adapters 7-place
UNIVERSAL 320 Blood Tube Package 2
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1589 | Adapters 7-place
  • 4x | 1588 | Adapters 5-place
UNIVERSAL 320 Conical Package 3
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1324 | Swing-out rotor, 4-place
  • 4x | 1398 | Buckets
  • 4x | 1483A | Adapters 4-place
  • 4x | 1484 | Adapters 1-place
UNIVERSAL 320 R Conical Package 1
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1577 | Adapters 2-place
  • 4x | 1579 | Adapters 1-place
UNIVERSAL 320 R Blood Tube Package 2
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1425 | Buckets
  • 4x | 1438 | Adapters 7-place
  • 4x | 1441 | Adapters 7-place
UNIVERSAL 320 R Conical Package 3
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1324 | Swing-out rotor, 4-place
  • 4x | 1398 | Buckets
  • 4x | 1483A | Adapters 4-place
  • 4x | 1484 | Adapters 1-place
UNIVERSAL 320 R Blood Tube Package 4
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1624 | Swing-out rotor, 4-place
  • 4x | 1481 | Buckets
  • 4x | 1492 | Lids (bioseal)
  • 4x | 1383 | Adapters 5-place
  • 4x | 1348 | Adapters 4-place
UNIVERSAL 320 R Blood Tube Package 5
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1589 | Adapters 7-place
  • 4x | 1588 | Adapters 5-place
UNIVERSAL 320 R Blood tube package 6
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1427 | buckets
  • 4x | 1421 | Lids (bioseal)
  • 4x | 1732 | Adapters 8-place
  • 4x | 5231 | Adapters 6-place
FAQ
How do benchtop centrifuges differ from small centrifuges?

HETTICH benchtop centrifuges specialize in variety. How is that? Because these centrifuges with their extensive accessories can be used for almost all standard applications. They are frequently used in clinical laboratories or food laboratories, for instance, or for agricultural purposes. The large capacity they offer, the option of cooling or heating the samples, and their higher speeds set them apart from small centrifuges. 

The rotor chamber heats up during centrifugation due to air friction and heat from the motor. The longer or faster the centrifugation, the higher the temperature. Laboratory centrifuges have an air cooling system fitted as standard that removes heat from the rotor chamber. However, many samples are thermally labile and have to be processed within a certain temperature range. Laboratory centrifuges with a coolant circuit and a controlled cooling unit are suitable for such samples. The preferred centrifugation temperature can be set within a range of -20°C to +40°C, depending on the design of the device. 

The actively heated centrifuge heats up quickly from room temperature to 90°C.

HETTICH offers three different cytodiagnostic systems. They can be used in the following centrifuges, depending on the system: ROTOFIX 32 A, UNIVERSAL 320 | R, ROTINA 380 | R, ROTINA 420 | R, ROTANTA 460 | R and ROTIXA 500 RS. Our cytology brochure provides a summary of these options.

In addition to providing our configurator, where you can put together your own customized combination, Hettich offers complete package sets. These centrifuge packages include everything you need for some of the most common applications. You'll find an overview of these packages here.

Product Support

Do you want to know more? Then reach out to us! Whether you prefer to send us a message, give us a call, or dive right into configuring your Centrifuge combination using our intuitive Configurator, we're here to ensure your experience is seamless and successful.

Centrifuge Configurator

RCF / RPM Calculator

Product catalog

Cleaning and care of centrifuges